Adjustment of welding gun DA2

Centering the foot base plate

Adjust the foot base plate so the distance between ceramic ferrule and stud (insulation pin) is the same all the way round. Otherwise the stud is hindered when dipping into the molten steel.

  • Slightly loosen the screws connecting the foot base plate and the pillars.

  • Shift the foot base plate until the distance between ceramic ferrule and stud (pin) is even.

  • Tighten the screws and the stud (pin).

  • Check the stud protrusion. If necessary, adjust again.

DA2 - ring lift

DA2 welding gun

DA2 is a stud welding gun that lifts the anchor through a ring, often called a ring lift gun. The lift can be adjusted from approx. 1 mm up to 4-5 mm. Different lift also gives a different welding arc - see the table below. Typical stud protrusion for this gun is X = 4-6 mm.

Adjustment of the lift

  • Turning the adjustment screw counterclockwise increases the lift by 0.2 mm per step.

  • Turning the adjustment screw clockwise reduces the lift by 0.2 mm per step.

Stud protrusion

Adjust the leg assembly so the stud (or insulation pin) stands about 5 mm out of the ceramic ferrule, X = 4-5 mm.

Welding parameters

Stud diameter (mm)

Welding time (s)

Welding current (A)

Lift / arc length (mm)

3

0.05

300

1.0

4

0.10

300

1.0

5

0.10

350

1.0

6

0.10

425

1.5

8

0.20

500

1.5-2.0

10

0.30

550

1.5-2.0

12

0.35

800

2.5

14

0.40

1000

2.5

16

0.45

1200

3.0

20

0.60

1600

4.0

22

0.80

2100

4.5

24

1.00

2200

4.5

25

1.20

2400

5.0

Dansk version: Justering af DA2.